КОНКУРЕНТНА ВАЛИДНОСТ MOTION X-RAY ТЕХНОЛОГИЈЕ КОЈА КОРИСТИ POLAR VERITY SENSE ЗА ПРОЦЕНУ БРЗИНЕ, СИЛЕ И СНАГЕ – ПИЛОТ СТУДИЈА

Autori

  • Jelena Aleksić University of Belgrade, Faculty of Sport and Physical Education, Belgrade, Serbia , Србија
  • Sofia Gkatzaveli 1. University of Belgrade, Faculty of Sport and Physical Education, Belgrade, Serbia 2. Athletopia, Thessaloniki, Greece , Србија
  • Lazar Tasić Nissatech Innovation Center, Niš, Serbia , Србија
  • Miloš Obrenović 1. D Gym, Belgrade, Serbia 2. The University "Union - Nikola Tesla", Belgrade, Serbia , Србија
  • Nenad Stojanović Nissatech Innovation Center, Niš, Serbia
  • Ivan Ćuk University of Belgrade, Faculty of Sport and Physical Education, Belgrade, Serbia , Србија https://orcid.org/0000-0001-7819-4384 (neautentifikovan)

DOI:

https://doi.org/10.22190/TEME230307045A

Ključne reči:

преносиви уређаји, евалуација, равни потисак са груди, кинетика, кинематика

Apstrakt

Процена силе, брзине и снаге је корисна како би се развиле различите способности спортисте и избегле потенцијалне повреде. Циљ ове студије је да процени конкурентну валидност коришћењем Polar Verity Sense сензора са Motion X-Ray технологијом како би се брзина, сила и снага у вежби равног потиска са груди процениле и упоредиле са златним стандардом (Qualisys 3D система). Ова пилот студија обављена је на узорку три мушка рекреативна вежбача старости 28 година, са између пет и десет година искуства и максималним потиском на клупи (1РМ) од 100 кг. Поступак тестирања је трајао два дана. Првог дана, 1РМ је процењен на Смит машини. После седам дана, учесници су извели две серије од седам понављања равног потиска са груди са 50 кг на истој машини. Прва серија је била пробна, док је друга коришћена за даље анализе. За анализе су коришћени Polar Verity Sense сензори са Motion X-Ray технологијом и 3Д кинематичка анализа са Qualisys системом. Резултати су показали да није било значајних статистичких разлика између ова два система (p < 0,05), док је Пирсонова корелација показала високу и значајну корелацију између њих (р > 0,692 < 0,999; p < 0,05). Ово истраживање поставља основу за нови процес мерења, који ће бити јефтинији и лакши. Будућа истраживања би могла да користе веће узорке испитаника, различите врсте вежби, као и брже покрете.

Reference

Akyildiz, Z., Yıldız, M., & Clemente, F. M. (2020). The reliability and accuracy of Polar Team Pro GPS units. Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology, 236, 83-89.

Baiget, E., Colomar, A., & Corbi, F. (2021). Importance of strength and power qualities for endurance athletes: A review. Journal of Human Kinetics, 78, 5-17.

Balsalobre-Fernández, C., Marchante, D., Baz-Valle, E., Alonso-Molero, I., Jiménez, S. L., & Muñóz-López, M. (2017). Analysis of wearable and smartphone-based technologies for the measurement of barbell velocity in different resistance training exercises. Frontiers in Physiology, 8.

Bangsbo, J. (1994). The physiology of soccer - with special reference to intense intermittent exercise. Acta Physiologica Scandinavica, 151(Suppl 619), 1-155.

Cerezuela Espejo, V., Belmonte, A., Courel Ibáñez, J., Conesa-Ros, E., Mora-Rodriguez, R., & Pallarés, J. G. (2020). Are we ready to measure running power? Repeatability and concurrent validity of five commercial technologies. European Journal of Sport Science, 21, 1-22.

Chaabene, H., Negra, Y., Bouguezzi, R., Mkaouer, B., Franchini, E., Julio, U., & Hachana, Y. (2017). Physical and physiological profile of wrestler athletes: a short review. Journal of Strength and Conditioning Research, 31(5), 1411-1442.

Cohen, J. (1988). Statistical power analysis for the behavioral sciences (2nd ed.). Hillsdale, NJ: Erlbaum.

Cormie, P., McGuigan, M. R., & Newton, R. U. (2011). Developing maximal neuromuscular power: part 2-training considerations for improving maximal power production. Sports Medicine, 41(2), 125-146.

Chaabene, H., Negra, Y., Bouguezzi, R., Mkaouer, B., Franchini, E., Julio, U., & Hachana, Y. (2019). Physical and physiological attributes of wrestlers: An update. Journal of Strength and Conditioning Research, 33(5), 1434-1456.

Chéry, C., & Ruf, L. (2019). Reliability of the load-velocity relationship and validity of the PUSH to measure velocity in the deadlift. Journal of Strength and Conditioning Research, 33(9), 2370-2380.

Crewther, B. T., Kilduff, L. P., Cunningham, D. J., Cook, C., Owen, N., & Yang, G. Z. (2011). Validating two systems for estimating force and power. International Journal of Sports Medicine, 32, 254-258.

Cronin, J., & Hansen, K. T. (2005). Strength and power predictors of sports speed. Journal of Strength and Conditioning Research, 19(2), 349-357.

Cronin, J. B., Hing, R. D., & McNair, P. J. (2004). Reliability and validity of a linear position transducer for measuring jump performance. Journal of Strength and Conditioning Research, 18, 590-593.

Cronin, J., & Sleivert, G. (2005). Challenges in understanding the influence of maximal power training on improving athletic performance. Sports Medicine, 35(3), 213-234.

Cuk, I., Markovic, M., Nedeljkovic, A., Ugarkovic, D., Kukolj, M., & Jaric, S. (2014). Force-velocity relationship of leg extensors obtained from loaded and unloaded vertical jumps. European Journal of Applied Physiology, 114(8), 1703–1714.

Dempster, W. T. (1955). Space requirements of the seated operator. WADC Technical Report, 55-159, Wright-Patterson Air Force Base.

Černe, T., Kamnik, R., Vesnicer, B., Gros, J. Ž. & Munih, M. (2013). Differences between elite, junior and non-rowers in kinematic and kinetic parameters during ergometer rowing. Human Movement Science, 32(4), 691-707.

Dorrell, H. F., Moore, J. M., Smith, M. F., & Gee, T. I. (2018). Validity and reliability of a linear positional transducer across commonly practised resistance training exercises. Journal of Sports Sciences, 36(21), 2405-2411.

Düking, P., Fuss, F. K., Holmberg, H. C., & Sperlich, B. (2018). Recommendations for assessment of the reliability, sensitivity, and validity of data provided by wearable sensors designed for monitoring physical activity. JMIR mHealth and uHealth, 6(4), e102.

Edouard, P., Lahti, J., Nagahara, R., Samozino, P., Navarro, L., Guex, K., & Mendiguchia, J. (2021). Low horizontal force production capacity during sprinting as a potential risk factor of hamstring injury in football. International Journal of Environmental Research and Public Health, 18(15), 7827.

Elliott, B. (2006). Biomechanics and tennis. British Journal of Sports Medicine, 40(5), 392-396.

Fullmer, W. B., Carrier, B., Malek, E., Gil, D., Cruz, K., Aguilar, C., Davis, D., Bodell, N., Montes, J., Manning, J., Debeliso, M., Navalta, J., & Lawrence, M. M. (2021). Validity of average heart rate and energy expenditure in Polar armband devices while self-paced biking. International Journal of Exercise Science: Conference Proceedings, 14(1), Article 26.

Fritschi, R. (2021). Validität von sechs Messsystemen bei der Bestimmung der Langhantelgeschwindigkeit. Master's thesis, Université de Fribourg.

Garnacho-Castaño, M. V., López-Lastra, S., & Maté-Muñoz, J. L. (2015). Reliability and validity assessment of a linear position transducer. Journal of Sports Science & Medicine, 14(1), 128-136.

Giatsis, G. (2001). The importance of the force-velocity relationship in resistance training. Strength and Conditioning Journal, 23(5), 27-29.

Gil, D., Carrier, B., Fullmer, W., Cruz, K., Aguilar, C. D., Davis, D. W., Malek, E. M., Bodell, N., Montes, J., Manning, J. W., Navalta, J. W., Lawrence, M. M., & DeBeliso, M. (2021). Validity of average heart rate and energy expenditure in Polar OH1 and Verity Sense while self-paced running. International Journal of Exercise Science: Conference Proceedings, 14(1), Article 27.

Gilgen-Ammann, R., Schweizer, T., & Wyss, T. (2019). RR interval signal quality of a heart rate monitor and an ECG Holter at rest and during exercise. European Journal of Applied Physiology, 119(7), 1525-1532.

Hansen, K. T., Cronin, J. B., & Newton, M. J. (2011). The reliability of linear position transducer and force plate measurement of explosive force–time variables during a loaded jump squat in elite athletes. Journal of Strength and Conditioning Research, 25(5), 1447-1456.

Hinde, K., White, G., & Armstrong, N. (2021). Wearable devices suitable for monitoring twenty-four hour heart rate variability in military populations. Sensors, 21(4), 1061.

Hoff, J., Kemi, O. J., & Helgerud, J. (2005). Strength and endurance differences between elite and junior elite ice hockey players: The importance of allometric scaling. International Journal of Sports Medicine, 26, 537-541.

Huggins, R. A., Giersch, G. E. W., Belval, L. N., Benjamin, C. L., Curtis, R. M., Sekiguchi, Y., Peltonen, J., & Casa, D. J. (2020). The validity and reliability of Global Positioning System units for measuring distance and velocity during linear and team sport simulated movements. Journal of Strength and Conditioning Research, 34(11), 3070-3077.

Jaric, S., & Markovic, G. (2009). Leg muscles design: the maximum dynamic output hypothesis. Medicine & Science in Sports & Exercise, 41(4), 780–787.

Jiménez-Reyes, P., Samozino, P., Brughelli, M., & Morin, J.-B. (2017). The Efficacy of Personalized Training Utilizing Force-Velocity Profiling during Jumping. Frontiers in Physiology, 7, 677.

Kilgallon, J., Cushion, E., Joffe, S., & Tallent, J. (2022). Reliability and validity of velocity measures and regression methods to predict maximal strength ability in the back-squat using a novel linear position transducer. Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology. Advance online publication.

Król, H., & Gołaś, A. (2017). Effect of Barbell Weight on the Structure of the Flat Bench Press. Journal of strength and conditioning research, 31(5), 1321–1337.

Künstlinger, U., Kramer, W., & Schmidtbleicher, D. (1987). Changes in muscle contractile properties and neural control during human muscular fatigue. Electroencephalography and Clinical Neurophysiology, 67(1), 9-21.

Lake, J., Augustus, S., Austin, K., Comfort, P., McMahon, J., Mundy, P., & Haff, G. G. (2019). The reliability and validity of the bar-mounted PUSH BandTM 2.0 during bench press with moderate and heavy loads. Journal of Sports Sciences, 37(23), 2685-2690.

Lake, J., Augustus, S., Austin, K., Mundy, P., McMahon, J., Comfort, P., & Haff, G. (2018). The validity of the Push Band 2.0 during vertical jump performance. Sports, 6(4), 140.

Leontijevic, B., Pazin, N., Kukolj, M., Ugarkovic, D., & Jaric, S. (2012). Selective effects of weight and inertia on maximum lifting. European Journal of Applied Physiology, 112(5), 1735-1743.

Merrigan, J., Stovall, J., Stone, J., Stephenson, M., Finomore, V., & Hagen, J. (2022). Validation of Garmin and Polar devices for continuous heart rate monitoring during common training movements in tactical populations. Measurement in Physical Education and Exercise Science. Advance online publication.

Morin, J. B., & Samozino, P. (2016). Interpreting power-force-velocity profiles for individualized and specific training. International Journal of Sports Physiology and Performance, 11(2), 267-272.

Motion X-Rays. (n.d.). Retrieved March 2, 2023, from https://www.motionxrays.com/

Newton, I. (1999). The Principia. Translated by I. Bernard Cohen and Anne Whitman. University of California Press, Berkeley.

Newton, R. U., Murphy, A. J., Humphries, B. J., Wilson, G. J., Kraemer, W. J., & Häkkinen, K. (1997). Influence of load and stretch shortening cycle on the kinematics, kinetics and muscle activation that occurs during explosive upper-body movements. European Journal of Applied Physiology and Occupational Physiology, 75, 333-342.

Nikolaidis, P. T., Fragkiadiakis, E. G., Papadopoulos, E. P., & Karydis, N. V. (2011). Effects of age on vertical jump parameters and anthropometric characteristics in basketball players. Journal of Strength and Conditioning Research, 25(10), 2909-2916.

Olstad, B. H., & Zinner, C. (2020). Validation of the Polar OH1 and M600 optical heart rate sensors during front crawl swim training. PLoS ONE, 15(4), e0231522.

Perez-Castilla, A., Piepoli, A., Delgado-Garcia, G., Garrido-Blanca, G., & Garcia-Ramos, A. (2019). Reliability and concurrent validity of seven commercially available devices for the assessment of movement velocity at different intensities during the bench press. Journal of Strength and Conditioning Research, 33(5), 1258-1265.

Picerno, P. (2017). Good Practice Rules for the Assessment of the Force-Velocity Relationship in Isoinertial Resistance Exercises. Asian Journal of Sports Medicine, 8(3), e15590. https://doi.org/10.5812/asjsm.15590

Polar Verity Sense. (n.d.). Retrieved February 20, 2023, from https://www.polar.com/us-en/products/accessories/verity-sense

Ранђеловић, Н., & Савић, З. (2016). Улога и значај школског спорта у процесу васпитања младих. TEME: Casopis za Društvene Nauke, 40(4).

Reid, K. F., & Fielding, R. A. (2011). Skeletal muscle power: a critical determinant of physical functioning in older adults. Exercise and Sport Sciences Reviews, 39(1), 12-17.

Schmidt, R. A., & Lee, T. D. (2019). Motor control and learning: A behavioral emphasis (6th ed.). Human Kinetics.

Speer, K. E., Semple, S., Naumovski, N., & McKune, A. J. (2020). Measuring heart rate variability using commercially available devices in healthy children: A validity and reliability study. European Journal of Investigation in Health, Psychology and Education, 10(1), 390-404.

Spudić, D., Cvitkovič, R., & Šarabon, N. (2021). Assessment and evaluation of force-velocity variables in flywheel squats: Validity and reliability of force plates, a linear encoder sensor, and a rotary encoder sensor. Applied Sciences, 11, 10541.

Sreckovic, S., Cuk, I., Djuric, S., Nedeljkovic, A., Mirkov, D., & Jaric, S. (2015). Evaluation of force–velocity and power–velocity relationship of arm muscles. European Journal of Applied Physiology, 115(8), 1779-1787.

Stone, M. H., Sands, W. A., Pierce, K. C., Carlock, J., Cardinale, M., & Newton, R. U. (2005). Relationship of maximum strength to weightlifting performance. Medicine and Science in Sports and Exercise, 37(6), 1037-1043.

Suchomel, T., Comfort, P., & Lake, J. (2017). Enhancing the force-velocity profile of athletes using weightlifting derivatives. Strength and Conditioning Journal, 39(1), 10-20.

Suzovic, D., Markovic, G., Pasic, M., & Jaric, S. (2013). Optimum load in various vertical jumps support the maximum dynamic output hypothesis. International Journal of Sports Medicine, 34(11), 1007–1014.

van den Tillaar, R., & Ettema, G. (2013). A comparison of muscle activity in concentric and counter movement maximum bench press. Journal of Human Kinetics, 38, 63-71.

van den Tillaar, R., & Ball, N. (2019). Validity and reliability of kinematics measured with PUSH Band vs. linear encoder in bench press and push-ups. Sports, 7(9), 207.

Wahl, Y., Düking, P., Droszez, A., Wahl, P., & Mester, J. (2017). Criterion-validity of commercially available physical activity tracker to estimate step count, covered distance and energy expenditure during sports conditions. Frontiers in Physiology, 8, 725.

Weakley, J., Morrison, M., García-Ramos, A., Johnston, R., James, L., & Cole, M. H. (2021). The validity and reliability of commercially available resistance training monitoring devices: A systematic review. Sports Medicine, 51(3), 443-502.

Whittle, M. W. (2007). Methods of gait analysis. In M. W. Whittle (Ed.), Gait Analysis (Fourth Edition) (pp. 137-175). Churchill Livingstone.

Zhu, W.-H., & Lamarche, T. (2007). Velocity estimation by using position and acceleration sensors. IEEE Transactions on Industrial Electronics, 54(5), 2710–2715.

Preuzimanja

Objavljeno

2023-12-25

Broj časopisa

Rubrika

Članci